A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the COPPER MOUNTAIN TECHNOLOGIES PLANAR R54 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   COPPER MOUNTAIN TECHNOLOGIES PLANAR R54   Description / Specification:    
COPPER MOUNTAIN TECHNOLOGIES PLANAR R54 5.4 GHz USB Vector Reflectometer

The Copper Mountain Planar R54 is a PC-driven vector reflectometer that operates in the frequency range from 85 MHz to 5.4 GHz. It is designed for use in the process of development, production, and field testing of various electronic devices in multiple environments, including operation as a component of an automated measurement system. The Planar R54 connects directly to the DUT without the use of a test cable, so there is higher calibration stability in the test setup and the cost of accessory replacement is signifi cantly decreased. Specifications. Impedance: 50 ohm (75 ohm connectors via adapters). Test port connector: N-type, male. Number of test ports: 1. Frequency range: 85 MHz to 5.4 GHz. Full CW frequency accuracy: ±6x10 ^-6. Frequency setting resolution: 10 Hz. Number of measurement points: 2 to 16,001. Measurement bandwidths: 100 Hz to 30 kHz (with 1/3 step). Cable loss measurement range: 35 dB. Accuracy of reflection measurements (magnitude / phase): -15 dB to 0 dB (0.4 dB / 4°), -25 dB to -15 dB (1.5 dB / 7°). Accuracy of transmission magnitude measurements -40 dB to 0 dB: 1.0 dB. Trace noise magnitude (high output power, IF bandwidth 1 kHz): 0.015 dB rms. Test Port Output power: High level -10 dBm, typ., Low level -30 dBm, typ. Damage level: +23 dBm. Measurement time per point: 200 µs.



 

Standard Calibration $730.00 *
*This is a Web introductory price for one calibration of the COPPER MOUNTAIN TECHNOLOGIES PLANAR R54. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your COPPER MOUNTAIN TECHNOLOGIES PLANAR R54 CALIBRATION and/or COPPER MOUNTAIN TECHNOLOGIES PLANAR R54 5.4 GHz USB Vector Reflectometer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: